Nội dung toàn văn Circular 24/2016/TT-BYT national technical regulation noise permissible exposure levels noise workplace
THE MINISTRY OF
HEALTH |
THE SOCIALIST
REPUBLIC OF VIETNAM |
No. 24/2016/TT-BYT |
Hanoi, June 30, 2016 |
CIRCULAR
NATIONAL TECHNICAL REGULATION ON NOISE - PERMISSIBLE EXPOSURE LEVELS OF NOISE IN THE WORKPLACE
Pursuant to the Law on Occupational Safety and Hygiene No. 84/2015/QH13 dated June 25, 2015;
Pursuant to the Law on Technical Regulations and Standards No. 68/2006/QH13 dated June 29, 2006;
Pursuant to the Government's Decree No. 127/2007/ND-CP dated August 01, 2007 specifying the implementation of a number of articles of the Law on Technical Regulations and Standards;
Pursuant to the Government's Decree No.63/2012/ND-CP dated August 31, 2012 defining the functions, tasks, powers and organizational structure of the Ministry of Health;
Upon the request of the Director of the Health Environment Management Agency;
The Minister of Health hereby introduces the Circular on national technical regulation on noise - permissible exposure levels of noise in the workplace.
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
QCVN 24/2016/BYT – the national technical regulation on noise - permissible exposure levels of noise in the workplace – shall be issued together with this Circular.
Article 2. Entry into force
This Circular shall enter into force from December 1, 2016.
Article 3. Implementation responsibility
The Director of Health Environment Management Agency, Director of Department/Agency/General Department of the Ministry of Health, Heads of bodies or entities directly affiliated to the Ministry, Directors of Health Departments of centrally-affiliated cities and provinces, Heads of Ministry-governed or sectoral health entities, shall be responsible for implementing this Circular./.
PP. THE
MINISTER
THE DEPUTY MINISTER
Nguyen Thanh Long
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
QCVN 24:2016/BYT
NATIONAL TECHNICAL REGULATION ON NOISE - PERMISSIBLE EXPOSURE LEVELS OF NOISE IN THE WORKPLACE
Preface
QCVN 24:2016/BYT is introduced by the Board on drafting of national technical regulation on the occupational hygiene, submitted by the Health Environment Management Agency for the Ministry’s approval and issued together with the Ministry of Health’s Circular No. 24/2016/TT-BYT dated June 30, 2016.
NATIONAL TECHNICAL REGULATION ON NOISE - PERMISSIBLE EXPOSURE LEVELS OF NOISE IN THE WORKPLACE
I. GENERAL PROVISIONS
1. Scope of application
This provides for permissible exposure levels of noise in the workplace.
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
This regulation shall apply to environmental regulatory authorities; occupational environment monitoring individuals or organizations; individuals or organizations having noise-emitting activities in the workplace causing impacts on employee's audibility.
This regulation shall not apply to those employees allowed to wear headphones at work.
II. TECHNICAL PROVISIONS
1. The permitted levels of an employee’s exposure to noise in the workplace shall not exceed the limit values described in the Table 1.
Table 1. Permissible exposure time for sound pressure levels
Noise exposure time
Equivalent permissible sound pressure levels (LAeq) - dBA
8 hours
85
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
88
2 hours
91
1 hour
94
30 minutes
97
15 minutes
100
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
103
3 minutes
106
2 minutes
109
1 minute
112
30 seconds
115
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
2. The permissible sound pressure limits at different work positions are regulated in the Table 2.
Table 2. Permissible octave band sound pressure levels at work positions
Work positions
General or equivalent sound pressure levels, not exceeding (dBA)
Sound pressure levels in octave bands with the centre frequencies thereof, not exceeding (dB)
63
125
250
500
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
2000
4000
8000
1. Direct or on-site work or production positions
85
99
92
86
83
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
78
76
74
2. Oversight and remote control booths not connected with communications telephones, laboratory or testing facilities, and engine or equipment rooms having noise sources
80
94
87
82
78
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
73
71
70
3. Oversight and remote control chambers connected with communications telephones, coordination divisions, or rooms equipped with precise machinery systems or typewriters
70
87
79
72
68
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
63
61
59
4. Functional, general administrative, accounting and planning departments
65
83
74
68
63
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
57
55
54
5. Brainwork, research and design, statistics, computer programming, theory testing and data processing divisions.
55
75
66
59
54
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
47
45
43
In every point of time when employees are at work, the maximum sound pressure level does not exceed 115 dBA.
3. Personal protective equipment: At work sites, unless there are solutions to reducing the sound pressure level by less than 85 dBA, measures to protect employee's hearing should be applied. Equipping employees at work with hearing protections must conform to requirements set out in the Table 3.
Table 3. Requirements for personal hearing protection
Sound pressure level (dBA)
Noise reduction efficiency of hearing protection (dBA)
<90
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
From 90 to <95
14-17
From 95 to <100
18-21
From 100 to <105
22-25
From 105 to <110
≥ 26
4. If employees expose to different sound pressure levels in a work shift, the overall noise exposure level does not exceed 1 and is calculated according to the following formula:
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
Where
D refers to the level of exposure to noise within a working day.
C1, C2 ,…. Cn refers to the 1st, 2nd,... nth actual exposure time equivalent to the actual noise level measured within that time.
T1, T2 …. Tn refers to the period of time during which exposure to noise is permitted, equivalent to the actual noise level measured within C1, C2, ….Cn.
III. IDENTIFICATION METHODS
Methods for measurement of noise emitted at work shall include:
1. TCVN 9799:2013 (ISO 9612:2009) Acoustics – Determination of occupational noise exposure level – Technical method.
2. 1910.95 App G (OSHA - Monitoring noise levels) method.
IV. REGULATORY PROVISIONS
...
...
...
Mọi chi tiết xin liên hệ: ĐT: (028) 3930 3279 DĐ: 0906 22 99 66
2. Employers must provide all personal protective equipment necessary for employees that ensure conformity with work environment requirements.
3. If noise emitted in the workplace exceeds the permitted limit, employers must promptly take actions to improve work conditions and protect employee's health.
V. IMPLEMENTATION
1. This regulation shall replace the standards for noise set out in the occupational hygiene standards issued together with the Decision No. 3733/2002/QD-BYT dated 10/10/2002 of the Minister of Health.
2. The Health Environment Management Agency, affiliated to the Ministry of Health, shall cooperate with relevant competent authorities on provision of guidance on, arrangement for and conduct of implementation of this regulation.
3. Based on practical regulatory requirements, the Health Environment Management Agency shall be responsible for submitting any request for the Ministry of Health’s amendment or supplementation where appropriate.
4. In cases where national or international standards on noise referred to in this regulation have been subject to amendment, supplementation or replacement, new ones shall be applied.