Quyết định 28/2002/QD-BBCVT

Decision No. 28/2002/QD-BBCVT of December 18, 2002, of the Minister of Posts and Telematics, promulgating the technical standards

Nội dung toàn văn Decision No. 28/2002/QD-BBCVT promulgating the technical standards


THE MINISTRY OF POST AND TELEMATICS
-------

THE SOCIALIST REPUBLIC OF VIETNAM
Independent - Freedom - Happiness
------------

No: 28/2002/QD-BBCVT

Hanoi, 18 December 2002

 

DECISION

OF THE MINISTER OF POSTS AND TELEMATICS PROMULGATING THE TECHNICAL STANDARDS

THE MINISTER OF POSTS AND TELEMATICS

Pursuant to the Ordinance on Goods Quality of January 04, 2000;

Pursuant to the Government's Decree No. 90/2002/ND-CP of November 11, 2002 on the functions, tasks, powers and organizational structure of the Ministry of Posts and Telematics;

Pursuant to the Decision No. 27/2001/QD-TCBD of January 09, 2001 of the Department General of Posts and Telecommunications (now the Ministry of Posts and Telematics) on establishing, promulgating and adopting standards;

At the proposal of the Director General of the Department of Science & Technology,

DECIDES

Article 1. To promulgate together with this Decision 04 technical standards on Telecommunication Terminal Equipment as follows:

1. ElectroMagnetic Compatibility (EMC) - Electrostatic discharge immunity - Testing and measurement techniques

Code: TCN 68-207: 2002

2. ElectroMagnetic Compatibility (EMC) - Voltage dips,short interruptions and voltage variations immunity - Testing and measurement techniques

Code: TCN 68-208: 2002

3. ElectroMagnetic Compatibility (EMC) - Surge immunity - Testing and measurement techniques

Code: TCN 68-209: 2002

4. ElectroMagnetic Compatibility (EMC) - Power frequency magnetic field immunity - Testing and measurement techniques

Code: TCN 68-210: 2002

Article 2. These technical standards mentioned in the Article 1 take effect 15 (fifteen) days after signing of this Decision.

Article 3. The Director General of the Ministry’s Office, the Director General of the Department of Science & Technology, the heads of the agencies attached to the Ministry of Posts and Telematics and organizations and individuals engaged shall have to implement this Decision.

 

 

FOR THE MINISTER OF POSTS AND TELEMATICS
STANDING DEPUTY MINISTER




Mai Liem Truc

 

TCN 68 - 210: 2002

ELECTROMAGNETIC COMPATIBILITY (EMC)

POWER FREQUENCY MAGNETIC FIELD IMMUNITY

TESTING AND MEASUREMENT TECHNIQUES

FOREWORD

The technical standard TCN 68 - 210: 2002 “ElectroMagnetic Compatibility (EMC) - Power frequency magnetic field immunity - Testing and measurement techniques” is based on the IEC 1000-4-8:1993 - Part 4 - Chapter 8.

The technical standard TCN 68 - 210: 2002 is drafted by Research Institute of Posts and Telecommunications (RIPT) at the proposal of Department of Science & Technology of Ministry of Posts and Telematics. The technical standard is adopted by the Decision No. 28/2002/QD-BBCVT of the Minister of Posts and Telematics dated 18/12/2002.

The technical standard TCN 68 - 210: 2002 is issued in a bilingual document (Vietnamese version and English version). In cases of interpretation disputes, Vietnamese version is applied.

 

ELECTROMAGNETIC COMPATIBILITY (EMC)

POWER FREQUENCY MAGNETIC FIELD IMMUNITY TESTING AND MEASUREMENT TECHNIQUES

(Issued together with the Decision No. 28/2002/QD-BBCVT of December 18, 2002 of the Minister of Posts and Telematics)

1. Scope

This technical standard specifies the immunity requirements of equipment, only under operational conditions, to magnetic disturbances at power frequency related to:

- Residential and commercial locations;

- Industrial installations and power plants;

- Medium voltage and high voltage sub-stations.

The applicability of this standard to equipment installed in different locations is determined by the presence of the phenomenon, as specified in clause 3.

This standard does not consider disturbances due to capacitive or inductive coupling in cables or other parts of the field installation. Other IEC standards dealing with conducted disturbances cover these aspects.

The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment for household, commercial and industrial applications when subjected to magnetic fields at power frequency (continuous and short duration field).

The standard defines:

- Recommended test levels;

- Test equipment;

- Test set-up;

- Test procedure.

Other kinds of magnetic fields would be object of standardization:

- Fields at the power frequencies (16 2/3 - 20 or 30 - 400 Hz);

- Fields of harmonic currents (100 Hz to 2000 Hz);

- Fields of higher frequencies (up to 150 kHz, e.g. for mains signalling systems);

- D.C. fields.

Note: This standard could be applied to telecommunication equipments.

2. Normative references

[1] IEC 60050 (161):1990, International Electrotechnical Vocabulary (IEV) - Chapter 161: Electromagnetic Compatibility (EMC).

[2] IEC 68-1: 1988, Environmental testing - Part 1: General and guidance.

3. General

The magnetic fields to which equipment is subjected may influence the reliable operation of equipment and systems.

The following tests ate intended to demonstrate the immunity of equipment when subjected to power frequency magnetic fields related to the specific location and installation condition of the equipment (e.g. proximity of equipment to the disturbance source).

The power frequency magnetic field is generated by power frequency current in conductors or, more seldom, from other devices (e.g. leakage of transformers) in the proximity of equipment.

As for the influence of nearby conductors, one should differentiate between:

- The current under normal operating conditions, which produces a steady magnetic field, with a comparatively small magnitude;

- The current under fault conditions which can produce comparatively high magnetic fields but of short duration, until the protection devices operate (a few milliseconds with fuses, a few seconds for protection relays).

The test with a steady magnetic field may apply to all types of equipment intended for public or industrial low voltage distribution networks or for electrical plants.

The test with a short duration magnetic field related to the fault conditions, requires test levels that differ from those for  steady state conditions; the highest values apply mainly to equipment to be installed in exposed places of electrical plants.

The test field waveform is that of power frequency.

In many cases (household areas, sub-stations and power plant under normal conditions), the magnetic field produced by harmonics is negligible. However, in very special cases like heavy industrial areas (large power converters, etc.) they occur, and will be considered in a future revision of this standard.

4. Definitions

4.1. EUT

Equipment under test.

4.2. Induction coil

Conductor loop of defined shape and dimensions, in which flows a current, generating a magnetic field of defined constancy in its plane and in the enclosed volume.

4.3. Induction coil factor

Ratio between the magnetic field strength generated by an induction coil of given dimensions and the corresponding current value; the field is that measured at the centre of the coil plane, without the EUT.

4.4. Immersion method

Method of application of the magnetic field to the EUT, which is placed in the centre of an induction coil (figure 1).

4.5. Proximity method

Method of application of the magnetic field to the EUT, where a small induction coil is moved along the side of the EUT in order to detect particularly sensitive areas.

4.6. Ground (reference) plane (GRP)

A flat conductive surface whose potential is used as a common reference for the magnetic field generator and the auxiliary equipment (the ground plane can be used to close the loop of the induction coil, as in figure 4). (IEV 161-04-36, modified).

4.7. Decoupling network, back filter

Electrical circuit intended to avoid reciprocal influence with other equipment not submitted to the magnetic field test.

5. Test levels

The preferential range of test levels, respectively for continuous and short duration application of the magnetic field, applicable to distribution networks at
50 Hz and 60 Hz, is given in table 1 and Table 2.

The magnetic field strength is expressed in A/m; 1 A/m corresponds to a free space induction of 1.26 mT.

Table 1: Test levels for continuous field

 

Table 2: Test levels for short duration: 1s to 3s

Level

Magnetic field strength

A/m

 

Level

Magnetic field strength

A/m

1

1

 

1

n.a.2)

2

3

 

2

n.a.2)

3

10

 

3

n.a.2)

4

30

 

4

300

5

100

 

5

1000

x1)

special

 

x1)

special

Note:

1- "x" is an open level. This level can be given in the product specification.

 

Notes:

1 - "x" is an open level. This level, as well the duration of the test, can be given in the product specification.

2 - "n.a." is not applicable

Information on the selection of the test levels is given in annex C. Information on actual levels is given in annex D.

6. Test equipment

The test magnetic field is obtained by a current flowing in an induction coil; The application of test field to the EUT is by the immersion method. An example of application of the immersion method is given in figure 1.

The test equipment includes the current source (test generator), the induction coil and auxiliary test instrumentation.

6.1. Test generator

The generator, with the output waveform corresponding to the test magnetic field, shall be able to deliver the required current in the induction coils specified in 6.2.

The generator power capability shall therefore be dimensioned by taking into account the coil impedance; the inductance may range from 2.5 mH for the 1m standard coil, to several mH (e.g. 6 mH) for a rectangular induction coil (1m ´ 2.6 m, see 6.2).

The specifications of the generator are:

- Current capability, determined by the maximum selected test level and induction coil factor (see 6.2.2 and annex A), ranging from 0.87 m-1 (1 m standard coil for testing table-top or small equipment) to 0.66 m-1 (rectangular induction coil, 1 m ´ 2.6 m, for testing floor standing or large equipment);

- Operability in short circuit condition;

- Low output terminal connected to the earth terminal (for connection to the safety earth of the laboratory);

- Precautions to prevent the emission of large disturbances that may be injected in the power supply network or may influence the test results.

The characteristics and performances of the current source or test generator for the different fields considered in this standard are give in 6.1.1.

6.1.1. Characteristics and performances of the test generator

The current source typically consists of a voltage regulator (connected to the mains distribution network), a current transformer and a circuit for the control of short duration application. The generator shall be able to operate in continuous mode or short duration mode.

Specifications

Output current range for continuous mode operation:

1 A to 100 A, divided by the coil factor

Output current range for short duration mode operation:

300 A to 1000 A, divided by the coil factor

Total distortion factor of the output current:

less than 8 %

Set time for short duration mode operation:

1s to 3s

Note:  The output current range, for the standard coil is from 1.2 A to 120 A for continuous mode, and from 350 A to 1200 A for short duration mode.

The waveform of the output current is a sinusoid.

The schematic circuit of the generator is given in figure 2.

6.1.2. Verification of the characteristics of the test generator

In order to compare the results for different test generators, the essential characteristics of the output current parameters shall be verified.

The output current shall be verified with the generator connected to the standard induction coil specified in 6.2.1.a; the connection shall be realized by twisted conductors of up to 3m length and suitable cross-section.

The emission of disturbances by the generator shall be verified (see 6.1).

The characteristics to be verified are:

- Output current value;

- Total distortion factor.

The verifications shall be carried out with a current probe and measurement instrumentation having ± 2% accuracy.

6.2. Induction coil

6.2.1. Characteristics of the induction coil

The induction coil, connected to the test generator previously defined (see 6.1.1), shall generate a field strength corresponding to the selected test level and the defined homogeneity.

The induction coil shall be made of copper, aluminum or any conductive non-magnetic material, of such cross-section and mechanical arrangement as to facilitate its stable positioning during the tests.

A same coil is suitable for the generation of the magnetic fields considered in this standard; it may be a "single turn" coil and shall have a suitable current capability, as may be necessary for the selected test level.

Multi-turn coils may be used in order to have a lower testing current.

Induction coil shall be adequately dimensioned to surround the EUT (three orthogonal positions).

Depending on the size of the EUT, induction coils of different dimensions may be used.

The dimensions recommended below are suitable for the generation of magnetic fields over the whole volume of the EUT's (table-top equipment or floor-standing equipment), with an acceptable variation of ± 3 dB.

The characteristics of induction coils in respect of the magnetic field distribution are given in annex B.

a) Induction coil for table-top equipment

The induction coil of standard dimensions for testing small equipment (e.g. computer monitors, watt-hour meters, transmitters for process control, etc.) has a square (or circular) form with 1 m side (or diameter), made of a conductor of relatively small cross-section.

The test volume of the standard square coil is 0.6 m ´ 0.6 m ´ 0.5 m (height).

A double coil of standard size (Helmholtz coil) could be used in order to obtain a field homogeneity better than 3 dB or for testing larger EUT's.

The double coil (Helmholtz coil) shall comprise of two or more series of turns, properly spaced (see figure 6, figure B.4, figure B.5).

The test volume of a double standard size coil, 0.8 m spaced, for a 3 dB homogeneity is 0.6 m ´ 0.6 m ´ 1 m (height).

For example, the Helmholtz coil, for a 0.2 dB inhomogeneity, have dimensions and separation distances as given in figure 6.

b) Induction coil for floor-standing equipment

Induction coils shall be made according to the dimensions of the EUT and the different field polarizations.

The coil shall be able to envelop the EUT; the coil dimensions shall be such as to give a minimum distance of coil conductors to EUT walls equal to 1/3 of the dimension of the EUT considered.

The coils shall be made of conductors of relatively small cross-section.

Note: Due to the possible large dimensions of EUT's, the coils may be made of "C" or "T" sections in order to have sufficient mechanical rigidity.

The test volume is determined by the testing area of the coil (60% ´ 60% of each side) multiplied by a depth corresponding to 50 % of shorter side of the coil.

6.2.2. Calibration of the induction coil, coil factor

In order to make it possible to compare the test results from different test equipment, the induction coils shall be calibrated in their operating condition, before conducting the test (without the EUT, in free space condition).

An induction coil of the correct dimensions for the EUT dimensions, shall be positioned at 1 m minimum distance from the wall of the laboratory and any magnetic material, by using insulating supports, and shall be connected to the test generator as prescribed in 6.1.2.

Appropriate magnetic field sensors shall be used to verify the magnetic field strength generated by the induction coil.

The field sensor shall be positioned at the centre of the induction coil (without the EUT) and with suitable orientation to detect the maximum value of the field.

The current in the induction coil shall be adjusted to the field strength specified by the test level.

The calibration shall be carried out at power frequency.

The calibration procedure shall be carried out with the test generator and induction coil.

The coil factor is determined (and verified) by the above procedure.

The coil factor gives the current value to be injected in the coil to obtain the required test magnetic field (H/I).

Information on the measurement of the test magnetic field is given in annex A.

6.3. Test and auxiliary instrumentation

6.3.1. Test instrumentation

The test instrumentation includes the current measuring system (sensors and instrument) for setting and measuring the current injected in the induction coil.

Note: The termination networks, back filters, etc. on power supply, control and signal lines that is part of the test set-up for other tests may be maintained.

The current measuring system is a calibrated current, measuring instrument, probe or shunt. The accuracy of the measurement instrumentation shall be ± 2%.

6.3.2. Auxiliary instrumentation

The auxiliary instrumentation comprises a simulator and any other instrument necessary for the operation and verification of the EUT functional specifications.

7. Test set-up

The test set-up comprises the following components:

- Ground (reference) plane (GRP);

- Equipment under test (EUT);

- Induction coil;

- Test generator.

Precautions shall be taken if the test magnetic field may interfere with the test instrumentation and other sensitive equipment in the vicinity of the test set-up.

Examples of test set-ups are given in the following figures:

Figure 3: Example of test set-up for table-top equipment

Figure 4: Example of test set-up for floor-standing equipment.

7.1. Ground (reference) plane

The ground plane (GPR) shall be placed in the laboratory: the EUT and auxiliary test equipment shall be placed on it and connected to it.

The ground plane shall be a non-magnetic metal sheet (copper or aluminum) of 0.25 mm thickness; other metals may be used but in this case they shall have 0.65 mm minimum thickness.

The minimum size of the ground plane is 1 m ´ 1 m.

The final size depends on the dimensions of the EUT.

The ground plane shall be connected to the safety earth system of the laboratory.

7.2. Equipment under test

The equipment is configured and connected to satisfy its functional requirements. It shall be placed on the GRP with the interposition of a 0.1 m thickness insulating support (e.g. dry wood).

The equipment cabinets shall be connected to the safety earth directly on the GRP via the earth terminal of the EUT.

The power supply, input and output circuits shall be connected to the sources of power supply, control and signal.

The cables supplied or recommended by the equipment manufacturer shall be used. In absence of any recommendation, unshielded cables shall be adopted, of a type appropriate for signals involved. All cables shall be exposed to the magnetic field for 1m of their length.

The back filters, if any, shall be inserted in the circuit at 1 m cable lengths from the EUT and connected to the ground plane.

The communication lines (data lines) shall be connected to the EUT by the cables given in the technical specification or standard for this application.

7.3. Test generator

The test generator shall be placed at less than 3 m distance from the induction coil. One terminal of the generator shall be connected to the ground plane as far as used.

7.4. Induction c;oil

The induction coil, of the type specified in 6.2.1, shall enclose the EUT placed at its centre.

Different induction coils may be selected for testing in the different orthogonal directions, according to the general criteria specified in 6.2.1 a) and b).

Induction coils used in the vertical position (horizontal polarization of the field) can be bonded (at the foot of one vertical conductor) directly to the ground plane, which represents the low side of the coil, as a part of it. In this case, 0.1 m minimum distance from EUT to the ground plane is sufficient.

The induction coil shall be connected to the test generator in the same way as for the calibration procedure specified in 6.2.2

The induction coil selected for the tests shall be specified in the test plan.

8. Test procedure

The test procedure shall include:

- Verification of the laboratory reference conditions;

- Preliminary verification of the correct operation of the equipment;

- Carrying out of the test;

- Evaluation of the test results.

8.1. Laboratory reference conditions

In order to minimize the effect of the environmental parameters on the test results, the test shall be carried out in climatic and electromagnetic reference conditions as specified in 8.1.1 and 8.1.2.

8.1.1. Climatic conditions

The test shall be carried out in standard climatic conditions in accordance with IEC 68-1:

- Temperature: 150C to 35oC;

- Relative humidity: 25% to 75%;

- Atmospheric pressure: 86 kPa to 106 kPa.

Note: Any  other value may be given in the product specifications.

8.1.2. Electromagnetic conditions

The electromagnetic conditions of the laboratory shall be such to guarantee the correct operation of the EUT in order not to influence the test results; otherwise, the tests shall be carried out in a Faraday cage.

In particular, the electromagnetic field value of the laboratory shall be at least 20 dB lower than the selected test level.

8.2. Carrying out the test

The test shall be carried out on the basis of a test plan including verification of the performances of the EUT as defined in the technical specification.

The power supply, signal and other functional electrical quantities shall be applied within their rated range.

If the actual operating signals are not available, they may be simulated.

Preliminary verification of equipment performances shall be carried out prior to applying the test magnetic field.

The test magnetic field shall be applied by the immersion method to the EUT, previously set-up as specified in 7.2.

The test level shall not exceed the product specification.

Note: In order to detect the most susceptible side/positions of the EUT, mainly of a stationary type, the proximity method may be used for investigation purposes. This method is not to be used for certification. An example of application of the test field by proximity method in given in figure 5.

The test field strength and the duration of the test shall be as determined by the selected test level, according to the different type of field (continuous of short duration field) established in the test plan.

a) Table-top equipment

The equipment shall be subjected to the test magnetic field by using the induction coil of standard dimensions (1 m ´ 1 m) specified in 6.2.1 a) and show in figure 3.

The induction coil shall then be rotated by 900 in order to expose the EUT to the test field with different orientations.

b) Floor-standing equipment

The equipment shall be subjected to the test magnetic field by using induction coils of suitable dimensions as specified in 6.2.1 b); the test shall be repeated by moving and shifting the induction coils, in order to test the whole volume of the EUT for each orthogonal direction.

The test shall be repeated with the coil shifted to different positions along the side of the EUT, in steps corresponding to 50% of the shortest side of the coil.

Note: The moving of the induction coil in steps corresponding to 50% of the shortest side of the coil gives overlapping test fields.

The induction coil shall then be rotated by 900 in order to expose the EUT to the test field with different orientations and the same procedure.

9. Test results and test report

This clause gives a guide for the evaluation of the test results and for the test report, related to this standard.

The variety and diversity of equipment and systems to be tested make the task of establishing the effects of this test on equipment and systems difficult.

The test results shall be classified on the basic of the operating conditions and the functional specifications of the equipment under test, as in the following, unless different specifications are given by product committees or product specifications:

1) Normal performance within the specifications limits;

2) Temporary degradation or loss of function or performance which is self-recoverable;

3) Temporary degradation or loss of function or performance which requires operator intervention or system reset;

4) Degradation or loss of function which is not recoverable due to damage of equipment (components) or software, or loss of data.

Equipment shall not become dangerous or unsafe as a result of the application of the tests defined in this standard.

In the case of acceptance tests, the test program and the interpretation of the test results have to be described in the specific product standard.

As general rule, the test result is positive if the equipment shows its immunity, for all the period of application of the test, and at the end of the tests the EUT fulfils the functional requirements established in the technical specification.

The technical specification may define effects on the EUT, that may be considered insignificant and therefore acceptable.

For these conditions it shall be verified that the equipment is able to recover its operative capabilities by itself at the end of the test; the time interval during which the equipment has lost its functional capabilities shall be therefore recorded. These verifications are binding for the definitive evaluation of the test result.

The test report shall include the test conditions and the test results.

Table-top equipment                                                      Floor-standing equipment

Figure 1: Example of application of the test field by the immersion method

Vr:        Voltage regulator

C:         Control circuit

Tc:        Current transformer

Figure 2:  Schematic circuit for the test generator for power frequency magnetic field

Figure 3: Example of test set-up for table-top equipment

Figure 4: Example of test set-up for floor-standing equipment

References common to figure 3 and figure 4

GRP:    Ground plane

C1:       Power supply circuit

A:         Safety earth

C2:       Signal circuit

S:         Insulating support

L:         Communication line

EUT:     Equipment under test

B:         To power supply source

Ic:         Induction coil

D:         To signal source, simulator

E:         Earth terminal

G:         To the test generator

Figure 5: Example of investigation of susceptibility to magnetic field by the proximity method

n:         Number of turns in each coil

a:         Separation of the coils

b:         Side of the coils (m)

I:          Current value (A)

H:         Magnetic field strength (A/m)

H:         1.22 ´ n/b ´ I

(with a = b/2.5 the non-homogeneity of the magnetic field strength is ± 0.2 dB)

Figure 6: Illustration of Helmholtz coils

 

ANNEX A

(Normative)

INDUCTION COIL CALIBRATION METHOD

A.1. Magnetic field measurement

The magnetic field test is related to free space condition, without the EUT and at 1m minimum distance from the laboratory walls and any magnetic material.

The measurement of the magnetic field may be done with a measurement system comprising of calibrated sensors e.g. a "Hall effect" of multi-turn loop sensor with a diameter of at least one order of magnitude smaller than the test induction coil and a power frequency narrow band instrument.

A.2. Calibration of the induction coil

The calibration shall be carried out by injecting the calibration current at power frequency in the induction coil and measuring the magnetic field by sensors placed at its geometrical centre.

Proper orientation of the sensor shall be selected in order to obtain the maximum value.

The "induction coil factor" shall be determined for each induction coil as the ratio "field strength/current" of injection (H/A).

The "coil factor", determined at a.c current, is not related to the current waveform, because it is a characteristic parameter of the induction coil; it is therefore applicable for the evaluation of magnetic field at power frequency.

For standard dimension coil, the coil factor is determined by the manufacturer of the coil, and can be verified by laboratory measurements before carrying out the tests.

 

ANNEX B

(Normative)

CHARACTERISTICS OF THE INDUCTION COILS

B.1. General

This annex considers the problems of generation of the test magnetic fields.

In the first stage, both the immersion and proximity methods were considered.

In order to know the limits of application of such methods, some questions have been emphasized.

In the following the reasons for the values are explained.

B.2. Induction coil requirements

The requirements of the induction coil is "3 dB tolerance of the test field in the volume of the EUT"; this tolerance has been considered a reasonable technical compromise in respect of a test characterized by severity levels in 10 dB steps, due to practical limits in the generation of constant field over a wide range of volumes.

The constancy of the field is a requirement limited to a single direction, orthogonal to the coil plane. The field in different directions is obtainable in successive test steps by rotating the induction coil.

B.3. Induction coil characteristics

The characteristics of induction coils of different dimensions suitable for testing table-top equipment or floor standing equipment are given in diagrams showing:

- Profile of the field generated by a square induction coil (1 m side) in its plane (see figure B.1);

- 3 dB area of the field generated by a square induction coil (1 m side) in its plane (see figure B.2);

- 3 dB area of the field generated by a square induction coil (1 m side) in the mean orthogonal plane (component orthogonal to the plane of the coil) (see figure B.3);

- 3 dB area of the field generated by two square induction coils (1 m side) 0.6 m spaced, in the mean orthogonal plane (component orthogonal to the plane of the coils) (see figure B.4);

- 3 dB area of the field generated by two square induction coils (1 m side) 0.8 m spaced, in the mean orthogonal plane (component orthogonal to the plane of the coils) (see figure B.5);

- 3 dB area of the field generated by a rectangular induction coil (1 m ´ 2.6 m) in its plane (see figure B.6);

- 3 dB area of the field generated by a rectangular induction coil (1 m ´ 2.6 m) in its plane (ground plane as a side of the induction coil) (see figure B.7);

- 3 dB area of the field generated by a rectangular induction coil (1 m ´ 2.6 m), with ground plane, in the mean orthogonal plane (component orthogonal to the plane of the coil) (see figure B.8).

In the selection of the form, arrangement and dimensions of the test coil, the following points have been considered:

- The 3 dB area, inside and outside the induction coil, is related to the shape and dimensions of the induction coil;

- For a given field strength, driving current value, power and energy of the test generator are proportional to the dimensions of the induction coil.

B.4. Summary of characteristics of induction coils

On the basic of the data on the field distribution of coils with different sizes, and in view of adopting the test method given in this standard to different classes of equipment, the conclusions that can be drawn are as follows:

- Single square coil, 1 m side: testing volume 0.6 m ´ 0.6 m ´ 0.5 m high (0.2 m minimum distance from EUT to the coil);

- Double square coils, 1 m side, 0.6 spaced: testing volume 0.6 m ´ 0.6 m ´ 1 m high (0.2 m minimum distance from EUT to the coil); increasing of the separation of the coils up to 0.8 m, extends the maximum high of testable EUT (see the 3 dB area, in the mean orthogonal plane) up to 1.2 m;

- Single rectangular coil, 1 m ´ 2.6 m: testing volume 0.6 m ´ 0.6 m ´ 2 m high (0.2 and 0.3 m minimum distance from EUT to the coil, respectively for the horizontal and vertical dimensions of EUT); if the induction coil is bonded to the GRP, a 0.1 m distance from it is sufficient.

Figure B.1: Characteristics of the field generated by a square induction coil (1 m side) in its plane.

Figure B.2: 3 dB area of the field generated by a square induction coil (1 m side) in its plane.

Figure B.3: 3 dB area of the field generated by a square induction coil (1 m side) in the mean orthogonal plane (component orthogonal to the plane of the coil).

Figure B.4: 3 dB area of the field generated by two square induction coils (1 m side) 0.6 m spaced, in the mean orthogonal plane (component orthogonal to the plane of the coils).

Figure B.5: 3 dB area of the field generated by two square induction coils (1 m side) 0.8 m spaced, in the mean orthogonal plane (component orthogonal to the plane of the coils).

Figure B.6: 3 dB area of the field generated by a rectangular induction coil (1 m ´ 2.6 m) in its plane.

Figure B.7: 3 dB area of the field generated by a rectangular induction coil (1 m ´ 2.6 m) in its plane (ground plane as a side of the induction coil).

Figure B.8: 3 dB area of the field generated by a rectangular induction coil (1 m ´ 2.6 m) with ground plane, in the mean orthogonal plane (component orthogonal to the plane of the coil).

 

ANNEX C

(Informative)

SELECTION OF THE TEST LEVELS

The test levels shall be selected in accordance with the most realistic installation and environmental conditions.

These levels are outlined in clause 5.

The immunity tests are correlated with these levels in order to establish a performance level for the environment in which the equipment is expected to operate. A survey of power frequency magnetic field strength is given in annex B.

The test level shall be chosen according to:

- The electromagnetic environment;

- The proximity of the disturbances sources to the equipment concerned;

- The compatibility margins.

Based on common installation practices, a guide for the selection of test levels for magnetic fields testing may be the following:

Class 1: Environmental level where sensitive device using electron beam can be used.

Monitors, electron microscope, etc, are representative of these devices.

Note: 90 % of the computer screens are submitted to only 1 A/m. However, screens located near source of disturbance such as transformers or power lines shall withstand higher levels to be set by product committees (other measures can be necessary like moving screens away from these sources).

Class 2: Well protected environment

The environment is characterized by the following attributes:

- Absence of electrical equipment like power transformers that may give rise to leakage fluxes;

- Areas not subjected to the influence of H.V. bus-bars.

Household, office, hospital protected areas far away from earth protection conductors, areas of industrial installations and H.V. sub-stations may be representative of this environment.

Class 3: Protected environment

The environment is characterized by the following attributes:

- Electrical equipment and cables that may give rise to leakage fluxes or magnetic field;

- Proximity of earth conductors of protection systems;

- M.V. circuits and H.V. bus-bars far away (a few hundred metres) from equipment concerned.

Commercial areas, control building, field of not heavy industrial plants, computer room of H.V. sub-stations may be representative of this environment.

Class 4: Typical industrial environment

The environment is characterized by the following attributes:

- Short branch power lines as bus-bars, etc;

- High power electrical equipment that may give rise to leakage fluxes;

- Ground conductors of protection system;

- M.V. circuits and H.V. bus-bars at relative distance (a few tens of metres) from equipment concerned.

Fields of heavy industrial and power plants and the control room of H.V. sub-stations may be representative of this environment.

Class 5: Severe industrial environment

The environment is characterized by the following attributes:

- Conductors, bus-bars or M.V., H.V. lines carrying tens of kA;

- Ground conductors of protection system;

- Proximity of  M.V. and H.V. bus-bars;

- Proximity of high power electrical equipment.

Switchyard areas of heavy industrial plants, M.V., H.V. and power stations may be representative of this environment

Class x: Special environment

The minor or major electromagnetic separation of interference sources from equipment circuits, cables, lines etc., and the quality of the installations may require the use of a higher or lower environmental level than those described above.

It should be noted that the equipment lines of a higher level can penetrate a lower severity environment.

 

ANNEX D

(Informative)

INFORMATION ON POWER FREQUENCY MAGNETIC FIELD STRENGTH

Data on the strength of the magnetic field considered are given below. Although not exhaustive, they may give information on the field strength expected at different locations and/or situations. Product committees may take them into account in the selection of the test levels, strictly related to each specific application.

Data are limited to available bibliography and/or measurements.

a) Household appliances

A survey on the magnetic fields produced by about 100 different appliances of 25 basic types is given in table D.1. The field strength is related to the surfaces of appliances (it is quite localized) and at greater distances. At a distance of 1 m or more it would vary from the maximum expected field at that distance by only 10% to 20% when measured in any direction from the appliance. Background magnetic field in the homes where appliances were measured ranged from 0.05 A/m to 0.1 A/m.

The faults in domestic low-voltage power lines gives field strength higher than specified, depending on the short circuit current of each installation; the duration is in the order of hundreds ms, depending on the protection devices installed.

Table D.1: Values of the maximum magnetic field produced by household appliances (results of the measurements of 100 different devices of 25 basic types).

Distance from the surface of the device

d = 0.3 m

d = 1.5 m

95% of the measurements

Highest measurements

0.03 A/m - 10 A/m

21 A/m

< 0.1="">

0.4 A/m

b) High voltage lines

Because the magnetic field is dependent on the line configuration, load and fault conditions, the field profile may be more significant to determine the electromagnetic environment to which equipment may be exposed.

General information on the environment produced by high voltage lines is given in IEC 1000-2-3.

The quantitative survey of the actual field measurement is given in table D.2.

Table D.2: Values of the magnetic field generated by a 400 kV line

Under the line tower

Under a mid span section

At 30 m lateral distance

10 A/m/kA

16 A/m/kA

about 1/3 of previous values

c) H.V. sub-station area

The quantitative survey of the actual field measurements related to 220 kV and 400 kV high voltage sub-stations area is given in table D.3.

Table D.3 - Values of the magnetic field in high voltage sub-station areas

Sub-station

220 kV

400 kV

Under the bus-bars near connection to a line carrying about 0.5 kA

14 A/m

9 A/m

In the relay room (kiosk)

Near event recorders at about 0.5 m distance: 3.3 A/m

Near measurement voltage transformer:

d = 0.1 m: 7.0 A/m

d = 0.3 m: 1.1 A/m

In the equipment room

Maximum 0.7 A/m

d) Power plants and industrial plants

Measurements were carried out at different areas of a power plant; most of them are comparable, for the kind of power supply lines and electrical equipment, to industrial plants.

The survey of the actual field measurement is given in table D.4

Table D.4: Values of the magnetic field in power plants

Source of magnetic field

Field (A/m) at a distance of:

0.3 m

0.5 m

1 m

1.5 m

Medium voltage bus-bars carrying 2.2 kA (*)

14 - 85

13.5 - 71

8.5 - 35

5.7

190 MVA, MV/HV transformer, 50% load

-

-

6.4

-

6 kV cells (*)

8 - 13

6.5 - 9

3.5 - 4.3

2 - 2.4

6 kV twisted power cables

-

2.5

-

-

6 MVA pumps (at full load, 0.65 kA)

26

15

7

-

600 kVA, MV/LV transformer

14

9.6

4.4

-

Control building, multipoint paper recorder

10.7

-

-

-

Control room, far away from sources

0.9

* These ranges include the values related to the different direction of the distance and geometry of the installation

 

Đã xem:

Đánh giá:  
 

Thuộc tính Văn bản pháp luật 28/2002/QD-BBCVT

Loại văn bảnQuyết định
Số hiệu28/2002/QD-BBCVT
Cơ quan ban hành
Người ký
Ngày ban hành18/12/2002
Ngày hiệu lực02/01/2003
Ngày công báo...
Số công báo
Lĩnh vựcCông nghệ thông tin
Tình trạng hiệu lựcCòn hiệu lực
Cập nhật18 năm trước
Yêu cầu cập nhật văn bản này

Download Văn bản pháp luật 28/2002/QD-BBCVT

Lược đồ Decision No. 28/2002/QD-BBCVT promulgating the technical standards


Văn bản bị sửa đổi, bổ sung

    Văn bản sửa đổi, bổ sung

      Văn bản bị đính chính

        Văn bản được hướng dẫn

          Văn bản đính chính

            Văn bản bị thay thế

              Văn bản hiện thời

              Decision No. 28/2002/QD-BBCVT promulgating the technical standards
              Loại văn bảnQuyết định
              Số hiệu28/2002/QD-BBCVT
              Cơ quan ban hànhViễn thông, Bộ Bưu chính
              Người ký***, Mai Liêm Trực
              Ngày ban hành18/12/2002
              Ngày hiệu lực02/01/2003
              Ngày công báo...
              Số công báo
              Lĩnh vựcCông nghệ thông tin
              Tình trạng hiệu lựcCòn hiệu lực
              Cập nhật18 năm trước

              Văn bản thay thế

                Văn bản được dẫn chiếu

                  Văn bản hướng dẫn

                    Văn bản được hợp nhất

                      Văn bản gốc Decision No. 28/2002/QD-BBCVT promulgating the technical standards

                      Lịch sử hiệu lực Decision No. 28/2002/QD-BBCVT promulgating the technical standards

                      • 18/12/2002

                        Văn bản được ban hành

                        Trạng thái: Chưa có hiệu lực

                      • 02/01/2003

                        Văn bản có hiệu lực

                        Trạng thái: Có hiệu lực